Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.734
Filtrar
1.
Int J Mol Sci ; 25(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38732218

RESUMO

Boronate esters are a class of compounds containing a boron atom bonded to two oxygen atoms in an ester group, often being used as precursors in the synthesis of other materials. The characterization of the structure and properties of esters is usually carried out by UV-visible, infrared, and nuclear magnetic resonance (NMR) spectroscopic techniques. With the aim to better understand our experimental data, in this article, the density functional theory (DFT) is used to analyze the UV-visible and infrared spectra, as well as the isotropic shielding and chemical shifts of the hydrogen atoms 1H, carbon 13C and boron 11B in the compound 4-(4,4,5,5-tetramethyl-1,3,2-dioxoborolan-2-yl)benzaldehyde. Furthermore, this study considers the change in its electronic and spectroscopic properties of this particular ester, when its boron atom is coordinated with a fluoride anion. The calculations were carried out using the LSDA and B3LYP functionals in Gaussian-16, and PBE in CASTEP. The results show that the B3LYP functional gives the best approximation to the experimental data. The formation of a coordinated covalent B-F bond highlights the remarkable sensitivity of the NMR chemical shifts of carbon, oxygen, and boron atoms and their surroundings. Furthermore, this bond also highlights the changes in the electron transitions bands n → π* and π → π* during the absorption and emission of a photon in the UV-vis, and in the stretching bands of the C=C bonds, and bending of BO2 in the infrared spectrum. This study not only contributes to the understanding of the properties of boronate esters but also provides important information on the interactions and responses optoelectronic of the compound when is bonded to a fluorine atom.


Assuntos
Benzaldeídos , Benzaldeídos/química , Espectroscopia de Ressonância Magnética , Teoria da Densidade Funcional , Flúor/química , Boro/química , Modelos Moleculares , Ésteres/química , Espectrofotometria Infravermelho , Estrutura Molecular , Íons/química
2.
Bull Environ Contam Toxicol ; 112(5): 71, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38684523

RESUMO

The remarkable optical properties and strong biocompatibility of carbon dots make them highly promising for applications in biochemical sensing and environmental testing. These carbon dots possess a surface that is easily modifiable. In this study, carbon dots have been successfully synthesized and modified by the addition of N and B dopants using the microwave method, along with the functionalization of their surface functional groups with bovine serum albumin (BSA). The maximum fluorescence intensity of N, B-CDs is observed at 462 nm when excited at a wavelength of 352 nm. N, B-CDs have a spherical size with a diameter ranging from 2 to 6 nm, confirmed by UV-Vis absorption spectra and the presence of functional groups in the FT-IR absorption patterns. BSA-functionalized N, B-CDs as the fluorescent probe demonstrate great potential as a sensor for Pb(II) ions in water, with a very low detection limit of 1.05 µg/L. This research could contribute to the development of fluorescence nanosensors.


Assuntos
Boro , Carbono , Chumbo , Nitrogênio , Pontos Quânticos , Chumbo/análise , Chumbo/química , Boro/química , Carbono/química , Nitrogênio/química , Nitrogênio/análise , Pontos Quânticos/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química , Soroalbumina Bovina/química , Monitoramento Ambiental/métodos , Espectrometria de Fluorescência , Corantes Fluorescentes/química
3.
Food Chem ; 449: 139264, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38593724

RESUMO

In this study, a microelectrode array sensor based on boron and nitrogen co-doped vertical graphene (BNVG) was assembled to quantify salicylic acid (SA) in living plants. The influence of B and N contents on the electrochemical reaction kinetics and SA response signal was investigated. A microneedle sensor with three optimized BNVG microelectrodes (3.57 at.% B and 3.27 at.% N) was used to quantitatively analyze SA in the 0.5-100 µM concentration range and pH 4.0-9.0, with limits of detection of 0.14-0.18 µM. Additionally, a quantitative electrochemical model database based on the BNVG microelectrode sensor was constructed to monitor the growth of cucumbers and cauliflowers, which confirmed that the SA level and plant growth rate were positively correlated. Moreover, the SA levels in various vegetables and fruits purchased from the market were measured to demonstrate the practical application prospects for on-site inspection and evaluation.


Assuntos
Boro , Técnicas Eletroquímicas , Frutas , Grafite , Microeletrodos , Nitrogênio , Ácido Salicílico , Verduras , Grafite/química , Ácido Salicílico/análise , Verduras/química , Frutas/química , Técnicas Eletroquímicas/instrumentação , Boro/química , Nitrogênio/análise , Agulhas , Cucumis sativus/química , Técnicas Biossensoriais/instrumentação , Limite de Detecção
4.
PLoS One ; 19(3): e0298331, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38530838

RESUMO

Electrochemical measurements, which exhibit high accuracy and sensitivity under low contamination, controlled electrolyte concentration, and pH conditions, have been used in determining various compounds. The electrochemical quantification capability decreases with an increase in the complexity of the measurement object. Therefore, solvent pretreatment and electrolyte addition are crucial in performing electrochemical measurements of specific compounds directly from beverages owing to the poor measurement quality caused by unspecified noise signals from foreign substances and unstable electrolyte concentrations. To prevent such signal disturbances from affecting quantitative analysis, spectral data of voltage-current values from electrochemical measurements must be used for principal component analysis (PCA). Moreover, this method enables highly accurate quantification even though numerical data alone are challenging to analyze. This study utilized boron-doped diamond (BDD) single-chip electrochemical detection to quantify caffeine content in commercial beverages without dilution. By applying PCA, we integrated electrochemical signals with known caffeine contents and subsequently utilized principal component regression to predict the caffeine content in unknown beverages. Consequently, we addressed existing research problems, such as the high quantification cost and the long measurement time required to obtain results after quantification. The average prediction accuracy was 93.8% compared to the actual content values. Electrochemical measurements are helpful in medical care and indirectly support our lives.


Assuntos
Cafeína , Café , Cafeína/análise , Boro/química , Eletrodos , Aprendizado de Máquina , Eletrólitos
5.
ACS Sens ; 9(3): 1611-1619, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38471116

RESUMO

Drug detection in biological solutions is essential in studying the pharmacokinetics of the body. Electrochemical detection is an accurate and rapid method, but measuring multiple drugs that react at similar potentials is challenging. Herein, we developed an electrochemical sensor using a boron-doped diamond (BDD) electrode modified with a molecularly imprinted polymer (MIP) to provide specificity in drug sensing. The MIP is a polymer material designed to recognize and capture template molecules, enabling the selective detection of target molecules. In this study, we selected the anticancer drug doxorubicin (DOX) as the template molecule. In the electrochemical measurements using an unmodified BDD, the DOX reduction was observed at approximately -0.5 V (vs Ag/AgCl). Other drugs, i.e., mitomycin C or clonazepam (CZP), also underwent a reduction reaction at a similar potential to that of DOX, when using the unmodified BDD, which rendered the accurate quantification of DOX in a mixture challenging. Similar measurements conducted in PBS using the MIP-BDD only resulted in a DOX reduction current, with no reduction reaction observed in the presence of mitomycin C and CZP. These results suggest that the MIP, whose template molecule is DOX, inhibits the reduction of other drugs on the electrode surface. Selective DOX measurement using the MIP-BDD was also possible in human plasma, and the respective limits of detection of DOX in PBS and human plasma were 32.10 and 16.61 nM. The MIP-BDD was durable for use in six repeated measurements, and MIP-BDD may be applicable as an electrochemical sensor for application in therapeutic drug monitoring.


Assuntos
Técnicas Eletroquímicas , Polímeros Molecularmente Impressos , Humanos , Técnicas Eletroquímicas/métodos , Boro/química , Mitomicina , Limite de Detecção , Eletrodos , Doxorrubicina
6.
Environ Pollut ; 347: 123705, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38442825

RESUMO

The ongoing challenge of water pollution by contaminants of emerging concern calls for more effective wastewater treatment to prevent harmful side effects to the environment and human health. To this end, this study explored for the first time the implementation of single-crystal boron-doped diamond (BDD) anodes in electrochemical wastewater treatment, which stand out from the conventional polycrystalline BDD morphologies widely reported in the literature. The single-crystal BDD presented a pure diamond (sp3) content, whereas the three other investigated polycrystalline BDD electrodes displayed various properties in terms of boron doping, sp3/sp2 content, microstructure, and roughness. The effects of other process conditions, such as applied current density and anolyte concentration, were simultaneously investigated using carbamazepine (CBZ) as a representative target pollutant. The Taguchi method was applied to elucidate the optimal operating conditions that maximised either (i) the CBZ degradation rate constant (enhanced through hydroxyl radicals (•OH)) or (ii) the proportion of sulfate radicals (SO4•-) with respect to •OH. The results showed that the single-crystal BDD significantly promoted •OH formation but also that the interactions between boron doping, current density and anolyte concentration determined the underlying degradation mechanisms. Therefore, this study demonstrated that characterising the BDD material and understanding its interactions with other process operating conditions prior to degradation experiments is a crucial step to attain the optimisation of any wastewater treatment application.


Assuntos
Poluentes Químicos da Água , Purificação da Água , Humanos , Boro/química , Oxirredução , Diamante/química , Poluentes Químicos da Água/química , Eletrodos , Purificação da Água/métodos
7.
Environ Sci Pollut Res Int ; 31(19): 28241-28252, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38538997

RESUMO

In this study, boron-doped porous carbon materials (BCs) with high surface areas were synthesized employing coffee grounds as carbon source and sodium bicarbonate and boric acid as precursors; afterward, nanoscale zero-valent iron (nZVI) and BCs composites (denoted as nZVI@BCs) were further prepared through reduction of FeSO4 by NaBH4 along with stirring. The performance of the nZVI@BCs for activating persulfate (PS) was evaluated for the degradation of bisphenol A (BPA). In comparison with nZVI@Cs/PS, nZVI@BCs/PS could greatly promote the degradation and mineralization of BPA via both radical and non-radical pathways. On the one hand, electron spin resonance and radical quenching studies represented that •OH, SO4•-, and O2•- were mainly produced in the nZVI@BCs/PS system for BPA degradation. On the other hand, the open circuit voltages of nZVI@BCs and nZVI@Cs in different systems indicated that non-radical pathway still existed in our system. PS could grab the unstable unpaired electron on nZVI@BCs to form a carbon material surface-confined complex ([nZVI@BCs]*) with a high redox potential, then accelerate BPA removal efficiency via direct electron transfer. Furthermore, the performances and mechanisms for BPA degradation were examined by PS activation with nZVI@BC composites at various conditions including dosages of nZVI@BCs, BPA and PS, initially pH value, temperature, common anions, and humid acid. Therefore, this study provides a novel insight for development of high-performance carbon catalysts toward environmental remediation.


Assuntos
Compostos Benzidrílicos , Boro , Carbono , Ferro , Fenóis , Compostos Benzidrílicos/química , Ferro/química , Boro/química , Carbono/química , Fenóis/química , Catálise , Porosidade
8.
ACS Sens ; 9(4): 1785-1798, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38384144

RESUMO

Real-time sensing of dopamine is essential for understanding its physiological function and clarifying the pathophysiological mechanism of diseases caused by impaired dopamine systems. However, severe fouling from nonspecific protein adsorption, for a long time, limited conventional neural recording electrodes concerning recording stability. This study reported a high-antifouling nanocrystalline boron-doped diamond microsensor grown on a carbon fiber substrate. The antifouling properties of this diamond sensor were strongly related to the grain size (i.e., nanocrystalline and microcrystalline) and surface terminations (i.e., oxygen and hydrogen terminals). Experimental observations and molecular dynamics calculations demonstrated that the oxygen-terminated nanocrystalline boron-doped diamond microsensor exhibited enhanced antifouling characteristics against protein adsorption, which was attributed to the formation of a strong hydration layer as a physical and energetic barrier that prevents protein adsorption on the surface. This finally allowed for in vivo monitoring of dopamine in rat brains upon potassium chloride stimulation, thus presenting a potential solution for the design of next-generation antifouling neural recording sensors. Experimental observations and molecular dynamics calculations demonstrated that the oxygen-terminated nanocrystalline boron-doped diamond (O-NCBDD) microsensor exhibited ultrahydrophilic properties with a contact angle of 4.9°, which was prone to forming a strong hydration layer as a physical and energetic barrier to withstand the adsorption of proteins. The proposed O-NCBDD microsensor exhibited a high detection sensitivity of 5.14 µA µM-1 cm-2 and a low detection limit of 25.7 nM. This finally allowed for in vivo monitoring of dopamine with an average concentration of 1.3 µM in rat brains upon 2 µL of potassium chloride stimulation, thus presenting a potential solution for the design of next-generation antifouling neural recording sensors.


Assuntos
Diamante , Dopamina , Dopamina/análise , Dopamina/química , Animais , Diamante/química , Interações Hidrofóbicas e Hidrofílicas , Ratos , Incrustação Biológica/prevenção & controle , Boro/química , Neurotransmissores/análise , Técnicas Biossensoriais/métodos , Adsorção , Simulação de Dinâmica Molecular , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Masculino , Nanopartículas/química
9.
Chem Rev ; 124(5): 2441-2511, 2024 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-38382032

RESUMO

Boron-containing compounds (BCC) have emerged as important pharmacophores. To date, five BCC drugs (including boronic acids and boroles) have been approved by the FDA for the treatment of cancer, infections, and atopic dermatitis, while some natural BCC are included in dietary supplements. Boron's Lewis acidity facilitates a mechanism of action via formation of reversible covalent bonds within the active site of target proteins. Boron has also been employed in the development of fluorophores, such as BODIPY for imaging, and in carboranes that are potential neutron capture therapy agents as well as novel agents in diagnostics and therapy. The utility of natural and synthetic BCC has become multifaceted, and the breadth of their applications continues to expand. This review covers the many uses and targets of boron in medicinal chemistry.


Assuntos
Boranos , Terapia por Captura de Nêutron de Boro , Neoplasias , Humanos , Boro/química , Química Farmacêutica , Compostos de Boro/química , Neoplasias/tratamento farmacológico , Ácidos Borônicos , Terapia por Captura de Nêutron de Boro/métodos
10.
Biosensors (Basel) ; 14(2)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38391994

RESUMO

Amperometry is arguably the most widely used technique for studying the exocytosis of biological amines. However, the scarcity of human tissues, particularly in the context of neurological diseases, poses a challenge for exocytosis research. Human platelets, which accumulate 90% of blood serotonin, release it through exocytosis. Nevertheless, single-cell amperometry with encapsulated carbon fibers is impractical due to the small size of platelets and the limited number of secretory granules on each platelet. The recent technological improvements in amperometric multi-electrode array (MEA) devices allow simultaneous recordings from several high-performance electrodes. In this paper, we present a comparison of three MEA boron-doped diamond (BDD) devices for studying serotonin exocytosis in human platelets: (i) the BDD-on-glass MEA, (ii) the BDD-on-silicon MEA, and (iii) the BDD on amorphous quartz MEA (BDD-on-quartz MEA). Transparent electrodes offer several advantages for observing living cells, and in the case of platelets, they control activation/aggregation. BDD-on-quartz offers the advantage over previous materials of combining excellent electrochemical properties with transparency for microscopic observation. These devices are opening exciting perspectives for clinical applications.


Assuntos
Serotonina , Humanos , Boro/química , Diamante/química , Eletrodos , Exocitose , Quartzo
11.
Anal Sci ; 40(5): 853-861, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38246930

RESUMO

To minimize background interference in electrochemical enzymatic biosensors employing electron mediators, it is essential for the electrochemical oxidation of electroactive interfering species (ISs), such as ascorbic acid (AA), to proceed slowly, and for the redox reactions between electron mediators and ISs to occur at a low rate. In this study, we introduce a novel combination of a working electrode and an electron mediator that effectively mitigates interference effects. Compared to commonly used electrodes such as Au, glassy carbon, and indium tin oxide (ITO), boron-doped diamond (BDD) electrodes demonstrate significantly lower anodic current (i.e., lower background levels) in the presence of AA. Additionally, menadione (MD) exhibits notably slower reactivity with AA compared to other electron mediators such as Ru(NH3)63+, 4-amino-1-naphthol, and 1,4-naphthoquinone, primarily due to the lower formal potential of MD compared to AA. This synergistic combination of BDD electrode and MD is effectively applied in three biosensors: (i) glucose detection using electrochemical-enzymatic (EN) redox cycling, (ii) glucose detection using electrochemical-enzymatic-enzymatic (ENN) redox cycling, and (iii) lactate detection using ENN redox cycling. Our developed approach significantly outperforms the combination of ITO electrode and MD in minimizing IS interference. Glucose in artificial serum can be detected with detection limits of ~ 20 µM and ~ 3 µM in EN and ENN redox cycling, respectively. Furthermore, lactate in human serum can be detected with a detection limit of ~ 30 µM. This study demonstrates sensitive glucose and lactate detection with minimal interference, eliminating the need for (bio)chemical agents to remove interfering species.


Assuntos
Boro , Diamante , Técnicas Eletroquímicas , Eletrodos , Glucose , Ácido Láctico , Vitamina K 3 , Diamante/química , Vitamina K 3/química , Boro/química , Glucose/análise , Glucose/química , Ácido Láctico/análise , Ácido Láctico/química , Técnicas Biossensoriais , Elétrons , Humanos , Oxirredução
12.
J Org Chem ; 89(3): 1556-1566, 2024 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-38227951

RESUMO

Over the last century, nucleoside-based therapeutics have demonstrated remarkable effectiveness in the treatment of a wide variety of diseases from cancer to HIV. In addition, boron-containing drugs have recently emerged as an exciting and fruitful avenue for medicinal therapies. However, borononucleosides have largely been unexplored in the context of medicinal applications. Herein, we report the synthesis, isolation, and characterization of two novel boron-containing nucleoside compound libraries which may find utility as therapeutic agents. Our synthetic strategy employs efficient one-step substitution reactions between a diverse variety of nucleoside scaffolds and an assortment of n-alkyl potassium trifluoroborate-containing electrophiles. We demonstrated that these alkylation reactions are compatible with cyclic and acyclic nucleoside substrates, as well as increasing alkyl chain lengths. Furthermore, regioselective control of product formation can be readily achieved through manipulation of base identity and reaction temperature conditions.


Assuntos
Boro , Nucleosídeos , Nucleosídeos/química , Boro/química , Compostos de Boro , Alquilação
13.
Environ Sci Pollut Res Int ; 31(8): 12207-12228, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38225497

RESUMO

The numerous oxidation states of the element boron bring great challenges in containing its contamination in receptor bodies. This scenario increases significantly due to the widespread use of boron compounds in various industries in recent years. For this reason, the removal of this contaminant is receiving worldwide attention. Although adsorption is a promising method in boron removal, finding suitable adsorbents, that is, those with high efficiency, and feasible remains a constant challenge. Hence, this review presents the boron removal methods in comparison to costs of adsorbents, reaction mechanisms, economic viability, continuous bed application, and regeneration capacity. In addition, the approach of multivariate algorithms in the solution of multiobjective problems can enable the optimized conditions of dosage of adsorbents and coagulants, pH, and initial concentration of boron. Therefore, this review sought to comprehensively and critically demonstrate strategic issues that may guide the choice of method and adsorbent or coagulant material in future research for bench and industrial scale boron removal.


Assuntos
Poluentes Químicos da Água , Purificação da Água , Purificação da Água/métodos , Boro/química , Adsorção , Poluentes Químicos da Água/análise , Água/química
14.
Luminescence ; 39(1): e4673, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38286598

RESUMO

YAG:Ce and LuAG:Ce ceramics are widely used as scintillator materials that convert high-energy radiation into visible light. For the practical application of such compounds, short decay times are a necessity. One way of shortening the existing decay times even more is to change the local environment of emitting ions by means of doping the matrix with additional elements, for example, boron or magnesium. Furthermore, boron ions also can help absorb gamma rays more efficiently, therefore improving overall applicability. Due to the aforementioned reasons, YAG and LuAG ceramics doped with cerium, boron, and magnesium were synthesized. Initial amorphous powders have been obtained by means of sol-gel synthesis and pressed into pellets under isostatic pressure and finally calcinated to form crystalline ceramics. The effects of boron and magnesium doping on the morphological, structural, and luminescence properties were investigated. The key results showed that doping with boron has indeed shortened the decay times of the garnet pellets. Overall, boron doping of ceramics is a relatively new research area; however, it is rather promising as it helps both to improve the luminescence properties and to increase particle growth rate.


Assuntos
Boro , Magnésio , Boro/química , Magnésio/química , Luminescência , Cerâmica , Íons
15.
Anal Biochem ; 685: 115386, 2024 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-37977214

RESUMO

In this study, the highly risky drug Edoxaban (EDX), which can threaten life and cause bleeding, was electro analytically evaluated. The electrochemical behavior of EDX was investigated using glassy carbon electrode (GCE) and boron-doped diamond electrode (BDDE). In this study, for the first time, a simple, rapid, sensitive, and selective voltammetric technique was developed by using different electrodes for the electrochemical characterization and detection of EDX. The optimized voltammetric technique showed anodic signals of EDX at +1.09 V and +1.08 V on GCE and BDDE, respectively, in BR (pH 5.0) solution. The developed voltammetric method provided a very good analytical working range for EDX in BR (pH 5.0) solution on GCE and BDDE, covering concentration ranges from 1.84 µM to 12.88 µM and from 3.68 µM to 14.72 µM, respectively. The limits of detection for EDX on GCE and BDDE under these experimental conditions were calculated as 0.24 µM and 0.57 µM, respectively. The developed voltammetric methods on both electrodes were successfully applied to urine and tablet samples. Additionally, the obtained voltammetric results were compared with UV-Vis spectroscopy results.


Assuntos
Boro , Carbono , Carbono/química , Boro/química , Análise Custo-Benefício , Eletrodos , Técnicas Eletroquímicas
16.
Int J Mol Sci ; 24(23)2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38069412

RESUMO

Boron neutron capture therapy (BNCT) is one of the most appealing radiotherapy modalities, whose localization can be further improved by the employment of boron-containing nanoformulations, but the fabrication of biologically friendly, water-dispersible nanoparticles (NPs) with high boron content and favorable physicochemical characteristics still presents a great challenge. Here, we explore the use of elemental boron (B) NPs (BNPs) fabricated using the methods of pulsed laser ablation in liquids as sensitizers of BNCT. Depending on the conditions of laser-ablative synthesis, the used NPs were amorphous (a-BNPs) or partially crystallized (pc-BNPs) with a mean size of 20 nm or 50 nm, respectively. Both types of BNPs were functionalized with polyethylene glycol polymer to improve colloidal stability and biocompatibility. The NPs did not initiate any toxicity effects up to concentrations of 500 µg/mL, based on the results of MTT and clonogenic assay tests. The cells with BNPs incubated at a 10B concentration of 40 µg/mL were then irradiated with a thermal neutron beam for 30 min. We found that the presence of BNPs led to a radical enhancement in cancer cell death, namely a drop in colony forming capacity of SW-620 cells down to 12.6% and 1.6% for a-BNPs and pc-BNPs, respectively, while the relevant colony-forming capacity for U87 cells dropped down to 17%. The effect of cell irradiation by neutron beam uniquely was negligible under these conditions. Finally, to estimate the dose and regimes of irradiation for future BNCT in vivo tests, we studied the biodistribution of boron under intratumoral administration of BNPs in immunodeficient SCID mice and recorded excellent retention of boron in tumors. The obtained data unambiguously evidenced the effect of a neutron therapy enhancement, which can be attributed to efficient BNP-mediated generation of α-particles.


Assuntos
Terapia por Captura de Nêutron de Boro , Nanopartículas , Camundongos , Animais , Boro/química , Terapia por Captura de Nêutron de Boro/métodos , Distribuição Tecidual , Camundongos SCID , Lasers
17.
Sensors (Basel) ; 23(20)2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37896690

RESUMO

Theophylline is a drug with a narrow therapeutic range. Electrochemical sensors are a potentially effective method for detecting theophylline concentration to prevent toxicity. In this work, a simple modification of a boron-doped diamond electrode using nickel nanoparticles was successfully performed for a theophylline electrochemical sensor. The modified electrode was characterized using a scanning electron microscope and X-ray photoelectron spectroscopy. Square wave voltammetry and cyclic voltammetry methods were used to study the electrochemical behavior of theophylline. The modified nickel nanoparticles on the boron-doped diamond electrode exhibited an electrochemically active surface area of 0.0081 cm2, which is larger than the unmodified boron-doped diamond's area of 0.0011 cm2. This modified electrode demonstrated a low limit of detection of 2.79 µM within the linear concentration range from 30 to 100 µM. Moreover, the modified boron-doped diamond electrode also showed selective properties against D-glucose, ammonium sulfate, and urea. In the real sample analysis using artificial urine, the boron-doped diamond electrode with nickel nanoparticle modifications achieved a %recovery of 105.10%, with a good precision of less than 5%. The results of this work indicate that the developed method using nickel nanoparticles on a boron-doped diamond electrode is promising for the determination of theophylline.


Assuntos
Boro , Nanopartículas , Boro/química , Níquel/química , Teofilina , Eletrodos
18.
Pharmacol Ther ; 251: 108548, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37858628

RESUMO

Boron has become a crucial weapon in anticancer research due to its significant intervention in cell proliferation. Being an excellent bio-isosteric replacement of carbon, it has modulated the anticancer efficacy of various molecules in the development pipeline. It has elicited promising results through interactions with various therapeutic targets such as HIF-1α, steroid sulfatase, arginase, proteasome, etc. Since boron liberates alpha particles, it has a wide-scale application in Boron Neutron Capture therapy (BNCT), a radiotherapy that demonstrates selectivity towards cancer cells due to high boron uptake capacity. Significant advances in the medicinal chemistry of boronated compounds, such as boronated sugars, natural/unnatural amino acids, boronated DNA binders, etc., have been reported over the past few years as BNCT agents. In addition, boronated nanoparticles have assisted the field of bio-nano medicines by their usage in radiotherapy. This review exclusively focuses on the medicinal chemistry aspects, radiotherapeutic, and chemotherapeutic aspects of boron in cancer therapeutics. Emphasis is also given on the mechanism of action along with advantages over conventional therapies.


Assuntos
Antineoplásicos , Terapia por Captura de Nêutron de Boro , Neoplasias , Humanos , Boro/uso terapêutico , Boro/química , Compostos de Boro/uso terapêutico , Compostos de Boro/química , Compostos de Boro/metabolismo , Neoplasias/tratamento farmacológico , Neoplasias/radioterapia , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Terapia por Captura de Nêutron de Boro/métodos
19.
Angew Chem Int Ed Engl ; 62(47): e202313166, 2023 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-37817512

RESUMO

Developing molecular fluorophores with enhanced fluorescence in aggregate state for the second near-infrared (NIR-II) imaging is highly desirable but remains a tremendous challenge due to the lack of reliable design guidelines. Herein, we report an aromatic substituent strategy to construct highly bright NIR-II J-aggregates. Introduction of electron-withdrawing substituents at 3,5-aryl and meso positions of classic boron dipyrromethene (BODIPY) skeleton can promote slip-stacked J-type arrangement and further boost NIR-II fluorescence of J-aggregates via increased electrostatic repulsion and intermolecular hydrogen bond interaction. Notably, NOBDP-NO2 with three nitro groups (-NO2 ) shows intense NIR-II fluorescence at 1065 nm and high absolute quantum yield of 3.21 % in solid state, which can be successfully applied in bioimaging, high-level encoding encryption, and information storage. Moreover, guided by this electron-withdrawing substituent strategy, other skeletons (thieno-fused BODIPY, aza-BODIPY, and heptamethine cyanine) modified with -NO2 are converted into J-type aggregates with enhanced NIR-II fluorescence, showing great potential to convert aggregation caused emission quenching (ACQ) dyes into brilliant J-aggregates. This study provides a universal method for construction of strong NIR-II emissive J-aggregates by rationally manipulating molecular packing and establishing relationships among molecular structures, intermolecular interactions, and fluorescence properties.


Assuntos
Elétrons , Dióxido de Nitrogênio , Corantes Fluorescentes/química , Compostos de Boro/química , Boro/química
20.
Chemosphere ; 345: 140396, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37820875

RESUMO

Tetrahydrofurfuryl alcohol (THFA), a widely applied raw materials, intermediate and solvent in the fields of agricultural, industry (especially in nuclear industry), is a potentially hazardous and non-biodegradable pollutant in wastewater. In this study, the electrochemical degradation pathways of THFA by a boron-doped diamond (BDD) anode with different current density (jappl = 20, 40 and 60 mA cm-2) and electrolyte solution (KNO3, KCl and K2SO4) was carefully investigated. The results exhibit that high chemical oxygen demand (COD) removal and mineralization rates were achieved by rapid non-selective oxidation in electrolyte solutions mediated by hydroxyl radicals (∙OH) and active chlorine (sulfate) under constant current electrolysis. In-depth data analysis using the high performance liquid chromatography and liquid chromatography/mass spectroscopy, the underlying removal pathways of THFA in KNO3, KCl and K2SO4 electrolyte solutions are proposed according to the effect of different mineralization mechanisms.


Assuntos
Boro , Poluentes Químicos da Água , Boro/química , Diamante/química , Poluentes Químicos da Água/análise , Sulfatos/química , Eletrodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA